Recommendations:

  • The configuration you did on the initial Step by Step instructions for Mach3 ,  Mach4 or UCCNC configured the control software and plugin, you just need to set the max spindle speed.
  • Keep in mind that you need to configure the VFD to take the control signals through the terminals:
    • COMMAND VALUE DESCRIPTION
      A001 01 Control terminals. 
      A002 01 Control Terminal
  • Run the spindle at different speeds and test with a DMM that you are getting a 0-10vdc from the analog output terminals that are proportional to the commanded speed.  The Relays should also activate to start the spindle in the commanded direction.  This will confirm that your configuration is OK.
  • Here is a link to the manual of the driver: https://www.hitachi.us/supportingdocs/forbus/inverters/Support/WJ200_Instruction_NT325X.pdf

 

Recommendations:

  • The configuration you did on the initial Step by Step instructions for Mach3 ,  Mach4 or UCCNC configured the control software and plugin, you just need to set the max spindle speed.
  • Keep in mind that you need to configure the VFD to take the control signals through the terminals:
    • COMMAND VALUE DESCRIPTION
      A001 01 Control terminals. 
      A002 01 Control Terminal
  • Run the spindle at different speeds and test with a DMM that you are getting a 0-10vdc from the analog output terminals that are proportional to the commanded speed.  The Relays should also activate to start the spindle in the commanded direction.  This will confirm that your configuration is OK.
  • Here is a link to the manual of the driver: https://www.hitachi.us/supportingdocs/forbus/inverters/Support/WJ200_Instruction_NT325X.pdf

 

Configuration de Min and  Max Spindle Speed.

  • Mach3
    Config / Spindle Pulleys

  • Mach4
    Config/Control/Spindle

  • UCCNC
    SETTINGS / SPINDLE